| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Terminal Type | Number of Turrets | Length - Above Board | Length - Below Flange | Length - Overall | Mounting Type | Termination | Flange Diameter | Diameter - Turret Head | Staking Side OD | Staking Side ID | Mounting Hole Diameter | Board Thickness | Contact Material | Contact Finish | Contact Finish Thickness | Insulation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2325-2-00-44-00-00-07-0TERM TURRET SINGLE L=2.77MM Mill-Max Manufacturing Corp. |
874 |
|
Datasheet |
2325 | Bulk | Active | Single End | Single | 0.109" (2.77mm) | 0.084" (2.13mm) | 0.193" (4.90mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.050" (1.27mm) | 0.070" (1.78mm) | 0.046" (1.17mm) | 0.073" (1.85mm) | 0.062" (1.57mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
|
2506-1-00-01-00-00-07-0TERM TURRET SINGLE L=3.96MM Mill-Max Manufacturing Corp. |
1,000 |
|
Datasheet |
2506 | Bulk | Active | Single End | Single | 0.156" (3.96mm) | 0.053" (1.35mm) | 0.209" (5.31mm) | Through Hole | Swage | 0.125" (3.18mm) | 0.093" (2.36mm) | 0.062" (1.57mm) | 0.043" (1.09mm) | 0.067" (1.70mm) | 0.031" (0.79mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
|
2307-3-00-50-00-00-07-0TERM TURRET DOUBLE L=4.72MM Mill-Max Manufacturing Corp. |
999 |
|
Datasheet |
2307 | Bulk | Active | Double End | Single, Double | 0.186" (4.72mm) | 0.195" (4.95mm) | 0.381" (9.68mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.050" (1.27mm) | 0.072" (1.83mm) | - | 0.076" (1.93mm) | 0.094" (2.39mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
|
2313-1-00-01-00-00-07-0TERM TURRET PIN L=1.98MM Mill-Max Manufacturing Corp. |
996 |
|
Datasheet |
2313 | Bulk | Active | Double End, Pin | Single | 0.078" (1.98mm) | 0.301" (7.65mm) | 0.379" (9.63mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.051" (1.30mm) | - | - | 0.076" (1.93mm) | 0.031" (0.79mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
|
2510-2-00-50-00-00-07-0TERM TURRET SINGLE L=3.45MM Mill-Max Manufacturing Corp. |
899 |
|
Datasheet |
2510 | Bulk | Active | Single End | Single | 0.136" (3.45mm) | 0.094" (2.39mm) | 0.230" (5.84mm) | Through Hole | Swage | 0.125" (3.18mm) | 0.062" (1.57mm) | 0.060" (1.52mm) | 0.042" (1.07mm) | 0.064" (1.63mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
|
2506-2-00-01-00-00-07-0TERM TURRET SINGLE L=3.96MM Mill-Max Manufacturing Corp. |
1,770 |
|
Datasheet |
2506 | Bulk | Active | Single End | Single | 0.156" (3.96mm) | 0.084" (2.13mm) | 0.240" (6.10mm) | Through Hole | Swage | 0.125" (3.18mm) | 0.093" (2.36mm) | 0.062" (1.57mm) | 0.043" (1.09mm) | 0.067" (1.70mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
|
2310-1-00-50-00-00-07-0TERM TURRET DOUBLE L=4.72MM Mill-Max Manufacturing Corp. |
999 |
|
Datasheet |
2310 | Bulk | Active | Double End | Single, Double | 0.186" (4.72mm) | 0.135" (3.43mm) | 0.321" (8.15mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.051" (1.30mm) | - | - | 0.067" (1.70mm) | 0.031" (0.79mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
|
2313-2-00-50-00-00-07-0TERM TURRET PIN L=1.98MM Mill-Max Manufacturing Corp. |
974 |
|
Datasheet |
2313 | Bulk | Active | Double End, Pin | Single | 0.078" (1.98mm) | 0.334" (8.48mm) | 0.412" (10.46mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.051" (1.30mm) | - | - | 0.076" (1.93mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
|
2348-2-00-44-00-00-07-0TERM TURRET SINGLE L=3.96MM Mill-Max Manufacturing Corp. |
464 |
|
Datasheet |
2348 | Bulk | Active | Single End | Double | 0.156" (3.96mm) | 0.084" (2.13mm) | 0.240" (6.10mm) | Through Hole | Swage | 0.094" (2.39mm) | 0.061" (1.55mm) | 0.061" (1.55mm) | 0.046" (1.17mm) | 0.064" (1.63mm) | 0.062" (1.57mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
|
2506-3-00-50-00-00-07-0TERM TURRET SINGLE L=3.96MM Mill-Max Manufacturing Corp. |
400 |
|
Datasheet |
2506 | Bulk | Active | Single End | Single | 0.156" (3.96mm) | 0.115" (2.92mm) | 0.271" (6.88mm) | Through Hole | Swage | 0.125" (3.18mm) | 0.093" (2.36mm) | 0.062" (1.57mm) | 0.043" (1.09mm) | 0.067" (1.70mm) | 0.094" (2.39mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |