| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CHB150-110S48RAILWAY BRICK DC-DC CHB150-110S4 |
2,772 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 48V | - | - | - | 3.125A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92% | - | - | Through Hole | Half Brick | Enable, Active High | CE, cURus | 60950-1 |
|
CHB150-110S24-CRAILWAY BRICK DC-DC CHB150-110S2 |
1,223 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 24V | - | - | - | 6.5A | 156 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92.5% | - | - | Through Hole | Half Brick | Enable, Active High | CE, cURus | 60950-1 |
|
CHB150-110S12N-CRAILWAY BRICK DC-DC I/P:66-160VD |
4,798 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 12V | - | - | - | 12.5A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92.5% | - | - | Through Hole | Half Brick | Enable, Active Low | CE, cURus | 60950-1 |
|
CHB150-110S12-CRAILWAY BRICK DC-DC CHB150-110S1 |
3,323 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 12V | - | - | - | 12.5A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92.5% | - | - | Through Hole | Half Brick | Enable, Active High | CE, cURus | 60950-1 |
|
CHB150-110S24N-CRAILWAY BRICK DC-DC I/P:66-160VD |
1,222 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 24V | - | - | - | 6.5A | 156 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92.5% | - | - | Through Hole | Half Brick | Enable, Active High | CE, cURus | 60950-1 |
|
CHB150-110S05N-CRAILWAY BRICK DC-DC I/P:66-160VD |
3,141 |
|
- |
CHB150-110S (150W) | Half Brick | Tray | Active | Isolated Module | 1 | 66V | 160V | 5V | - | - | - | 30A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 100°C | 92.5% | - | - | Through Hole | Half Brick | Enable, Active Low | CE, cURus | 60950-1 |
|
VKP60LT512CDC DC CONVERTER 5.1V +/-12V 60W |
3,039 |
|
Datasheet |
VKP60xTC (60W) | 12-DIP Module, 1/2 Brick | Tube | Obsolete | Isolated Module | 3 | 18V | 36V | 5.1V | 12V | -12V | - | 12A, 2.5A, 2.5A | 60 W | 1.5 kV | ITE (Commercial) | - | -40°C ~ 100°C | 87% | - | - | Through Hole | - | - | - | - |
|
VKP60LT515CDC DC CONVERTER 5V +/-15V 60W |
4,771 |
|
Datasheet |
VKP60xTC (60W) | 12-DIP Module, 1/2 Brick | Tube | Obsolete | Isolated Module | 3 | 18V | 36V | 5V | 15V | -15V | - | 12A, 2A, 2A | 60 W | 1.5 kV | ITE (Commercial) | - | -40°C ~ 100°C | 87% | - | - | Through Hole | - | - | - | - |
|
ERM01U100100W 1/4 BRICK, 36-160VDC IN, 54 |
1,742 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 54V | - | - | - | 1.85A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 50155; 62368-1 |
|
ERM20A100N100W 1/4 BRICK, NEG-ENABLE, 36-1 |
1,395 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 5V | - | - | - | 20A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 91.5% | - | - | Through Hole | - | Enable, Active Low | CE, UKCA | 50155; 62368-1 |
|
ERM08B100100W 1/4 BRICK, 36-160VDC IN, 12 |
4,751 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 12V | - | - | - | 8.4A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 91% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 50155; 62368-1 |
|
ERM04H100100W 1/4 BRICK, 36-160VDC IN, 24 |
2,571 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 24V | - | - | - | 4.2A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 50155; 62368-1 |
|
ERM06C100100W 1/4 BRICK, 36-160VDC IN, 15 |
1,602 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 15V | - | - | - | 6.7A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 90.5% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 50155; 62368-1 |
|
ERM01U100N100W 1/4 BRICK, NEG-ENABLE, 36-1 |
3,297 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 54V | - | - | - | 1.85A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | - | Enable, Active Low | CE, UKCA | 50155; 62368-1 |
|
ERM20A100100W 1/4 BRICK, 36-160VDC IN, 5V |
2,678 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 5V | - | - | - | 20A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 91.5% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 50155; 62368-1 |
|
ERM06C100N100W 1/4 BRICK, NEG-ENABLE, 36-1 |
2,502 |
|
Datasheet |
ERM100 (100W) | 8-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 160V | 15V | - | - | - | 6.7A | 100 W | 2 kV | ITE (Commercial), Railway | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 90.5% | - | - | Through Hole | - | Enable, Active Low | CE, UKCA | 50155; 62368-1 |
|
HBS100YG-ANTDC DC CONVERTER 5V 100W |
3,474 |
|
Datasheet |
HBS (100W) | 9-DIP Module, 1/2 Brick | Bulk | Obsolete | Isolated Module | 1 | 18V | 36V | 5V | - | - | - | 20A | 100 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP | -40°C ~ 100°C | 83% | - | - | Through Hole | - | Enable, Active Low | - | - |
|
CQB150W-110S48-CRAILWAY BRICK DC-DC I/P:43-160VD |
4,865 |
|
- |
CQB150W-110S (150W) | Quarter Brick | Box | Active | Isolated Module | 1 | 43V | 160V | 48V | - | - | - | 3.2A | 154 W | 3 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 105°C | 90.5% | - | - | Through Hole | Quarter Brick | Enable, Active High | CB, CE, cURus | 60950-1 |
|
CQB150W-110S3V3RAILWAY BRICK DC-DC I/P:43-160VD |
4,905 |
|
- |
CQB150W-110S (150W) | Quarter Brick | Box | Active | Isolated Module | 1 | 43V | 160V | 3.3V | - | - | - | 30A | 100 W | 3 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 105°C | 89% | - | - | Through Hole | Quarter Brick | Enable, Active High | CB, CE, cURus | 60950-1 |
|
CQB150W-110S3V3NRAILWAY BRICK DC-DC I/P:43-160VD |
4,931 |
|
- |
CQB150W-110S (150W) | Quarter Brick | Box | Active | Isolated Module | 1 | 43V | 160V | 3.3V | - | - | - | 30A | 100 W | 3 kV | ITE (Commercial) | Adjustable Output, Remote On/Off | -40°C ~ 105°C | 89% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CB, CE, cURus | 60950-1 |