| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RP40-1103.3SFR/P-HCDC DC CONVERTER 3.3V 33W |
4,409 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 1 | 43V | 160V | 3.3V | - | - | - | 10A | 33 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | 6-DIP Module | Enable, Active High | - | - |
|
RP40-1103.3SFR/N-HCDC DC CONVERTER 3.3V 33W |
1,847 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 1 | 43V | 160V | 3.3V | - | - | - | 10A | 33 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | 6-DIP Module | Enable, Active Low | - | - |
|
RP40-11005SFR/P-HCDC DC CONVERTER 5V 40W |
3,007 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 1 | 43V | 160V | 5V | - | - | - | 8A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active High | - | - |
|
RP40-11005SFR/N-HCDC DC CONVERTER 5V 40W |
4,496 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 1 | 43V | 160V | 5V | - | - | - | 8A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active Low | - | - |
|
RP40-11012DFR/P-HCDC DC CONVERTER +/-12V 40W |
4,459 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 12V | -12V | - | - | 1.666A, 1.666A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active High | - | - |
|
RP40-11012DFR/N-HCDC DC CONVERTER +/-12V 40W |
3,809 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 12V | -12V | - | - | 1.666A, 1.666A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active Low | - | - |
|
RP40-11015DFR/P-HCDC DC CONVERTER +/-15V 40W |
4,667 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 15V | -15V | - | - | 1.333A, 1.333A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active High | - | - |
|
RP40-11015DFR/N-HCDC DC CONVERTER +/-15V 40W |
2,908 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 15V | -15V | - | - | 1.333A, 1.333A | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | 6-DIP Module | Enable, Active Low | - | - |
|
RP40-11024DFR/P-HCDC DC CONVERTER +/-24V 40W |
3,541 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 24V | -24V | - | - | 833mA, 833mA | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | 6-DIP Module | Enable, Active High | - | - |
|
RP40-11024DFR/N-HCDC DC CONVERTER +/-24V 40W |
3,982 |
|
Datasheet |
POWERLINE RP40-FR (40W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 43V | 160V | 24V | -24V | - | - | 833mA, 833mA | 40 W | 3 kV | ITE (Commercial), Railway | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | 6-DIP Module | Enable, Active Low | - | - |
|
PT4481NDC DC CONVERTER 1.3-3.5V 100W |
4,288 |
|
Datasheet |
Excalibur™ PT4480 (100W) | 26-SIP Module | Tray | Obsolete | Isolated Module | 1 | 36V | 75V | 1.3 ~ 3.5V | - | - | - | 30A | 100 W | 1.5 kV | ITE (Commercial) | - | -40°C ~ 85°C | 89% | - | - | Through Hole | - | - | - | - |
|
VCB4812QBO-800WR3A-NISOLATED MODULE DC DC CONVERTER |
4,495 |
|
Datasheet |
VCB48_QBO-800WR3A-N (800W) | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 40V | 60V | 12V | - | - | - | 66.6A | 799 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Load Sharing, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 96.6% | - | - | Through Hole | Quarter Brick | Enable, Active Low | - | 62368-1 |
|
VCB4810QBO-800WR3A-NISOLATED MODULE DC DC CONVERTER |
4,611 |
|
Datasheet |
VCB48_QBO-800WR3A-N (800W) | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 40V | 60V | 10.8V | - | - | - | 66.6A | 719 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Load Sharing, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 96.3% | - | - | Through Hole | Quarter Brick | Enable, Active Low | - | 62368-1 |
|
VCB4812QBO-800WR3D-NISOLATED MODULE DC DC CONVERTER |
4,569 |
|
Datasheet |
VCB48_QBO-800WR3AD-N (800W) | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 40V | 60V | 12.1V | - | - | - | 66.6A | 806 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Load Sharing, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 96.6% | - | - | Through Hole | Quarter Brick | Enable, Active Low | - | 62368-1 |
|
VCB4810QBO-800WR3D-NISOLATED MODULE DC DC CONVERTER |
4,014 |
|
Datasheet |
VCB48_QBO-800WR3AD-N (800W) | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 40V | 60V | 10.9V | - | - | - | 66.6A | 726 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Load Sharing, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 96.3% | - | - | Through Hole | Quarter Brick | Enable, Active Low | - | 62368-1 |
|
CN50B110-48/CODC-DC, RAILWAY, 52.8W, 43-160V, |
1,363 |
|
Datasheet |
CN-B110 (50W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 43V | 160V | 48V | - | - | - | 1.1A | 300 W | 3 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 100°C | 87% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus, TUV, UKCA | 50155; 62368-1 |
|
CN50B110-5/CODC-DC, RAILWAY, 50W, 43-160V, 5V |
1,771 |
|
Datasheet |
CN-B110 (50W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 43V | 160V | 5V | - | - | - | 10A | 300 W | 3 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 100°C | 89.5% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus, TUV, UKCA | 50155; 62368-1 |
|
CN50B110-24/CODC-DC, RAILWAY, 50.4W, 43-160V, |
3,770 |
|
Datasheet |
CN-B110 (50W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 43V | 160V | 24V | - | - | - | 2.1A | 300 W | 3 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 100°C | 89% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus, TUV, UKCA | 50155; 62368-1 |
|
CN50B110-12/CODC-DC, RAILWAY, 50.4W, 43-160V, |
4,536 |
|
Datasheet |
CN-B110 (50W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 43V | 160V | 12V | - | - | - | 4.2A | 300 W | 3 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 100°C | 88% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus, TUV, UKCA | 50155; 62368-1 |
|
CN50B110-15/CODC-DC, RAILWAY, 51W, 43-160V, 15 |
2,369 |
|
Datasheet |
CN-B110 (50W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 43V | 160V | 15V | - | - | - | 3.4A | 300 W | 3 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | -40°C ~ 100°C | 87.5% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus, TUV, UKCA | 50155; 62368-1 |