| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CQB50W8-36S15NRAILWAY BRICK DC-DC I/P:9-75VDC |
1,653 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 15V | - | - | - | 3.33A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Full Brick | Enable, Active Low | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S28NRAILWAY BRICK DC-DC I/P:9-75VDC |
2,794 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 28V | - | - | - | 1.79A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Full Brick | Enable, Active Low | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S12NRAILWAY BRICK DC-DC I/P:9-75VDC |
4,010 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 12V | - | - | - | 4.17A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | Full Brick | Enable, Active Low | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S48RAILWAY BRICK DC-DC I/P:9-75VDC |
2,671 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 48V | - | - | - | 1.05A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | Full Brick | Enable, Active High | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S24NRAILWAY BRICK DC-DC I/P:9-75VDC |
4,324 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 24V | - | - | - | 2.08A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Full Brick | Enable, Active Low | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S24RAILWAY BRICK DC-DC I/P:9-75VDC |
4,608 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 24V | - | - | - | 2.08A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Full Brick | Enable, Active High | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S28RAILWAY BRICK DC-DC I/P:9-75VDC |
1,067 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 28V | - | - | - | 1.79A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Full Brick | Enable, Active High | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S12RAILWAY BRICK DC-DC I/P:9-75VDC |
2,513 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 12V | - | - | - | 4.17A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | Full Brick | Enable, Active High | CB, CE, cURus, UKCA | 62368-1 |
|
CQB50W8-36S48NRAILWAY BRICK DC-DC I/P:9-75VDC |
4,365 |
|
- |
CQB50W8 (50W) | Full Brick | Box | Active | Isolated Module | 1 | 9V | 75V | 48V | - | - | - | 1.05A | 50 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | Full Brick | Enable, Active Low | CB, CE, cURus, UKCA | 62368-1 |
|
AVE450B-48S28-6L/MDC DC CONVERTER 28V 450W |
1,284 |
|
Datasheet |
AVE450 (450W) | 9-DIP Module, 1/2 Brick | Tray | Active | Isolated Module | 1 | 36V | 75V | 28V | - | - | - | 16A | 450 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, UVLO | -40°C ~ 85°C | 94% | - | - | Through Hole | - | - | - | - |
|
AVE450-48S50-6LDC DC CONVERTER 50V 450W |
4,328 |
|
Datasheet |
AVE450 (450W) | Half Brick | Tray | Active | Isolated Module | 1 | 36V | 75V | 50V | - | - | - | 9A | 450 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OTP, OVP | -40°C ~ 85°C | 95% | - | - | Through Hole | Half Brick | - | - | - |
|
AVE450-48S50P-6LDC DC CONVERTER 50V 450W |
4,787 |
|
Datasheet |
AVE450 (450W) | Half Brick | Tray | Active | Isolated Module | 1 | 36V | 75V | 50V | - | - | - | 9A | 450 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OTP, OVP | -40°C ~ 85°C | 95% | - | - | Through Hole | Half Brick | - | - | - |
|
PRQ150W-Q48-S15-H-DDC DC CONVERTER 15V 150W |
1,953 |
|
Datasheet |
PRQ150W | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 18V | 75V | 15V | - | - | - | 10A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Heat Sink, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | Quarter Brick | - | CE | 62368-1 |
|
PRQ150W-Q48-S5-H-DDC DC CONVERTER 5V 150W |
2,404 |
|
Datasheet |
PRQ150W | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 18V | 75V | 5V | - | - | - | 30A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Heat Sink, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 88% | - | - | Through Hole | Quarter Brick | - | CE | 62368-1 |
|
JVA401500S12DC DC CONVERTER 12V 40W |
1,163 |
|
Datasheet |
JVA40 (40W) | 5-DIP Module | Box | Obsolete | Isolated Module | 1 | 200V | 1500V | 12V | - | - | - | 3.33A | 40 W | 4 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 70°C (With Derating) | 72% | - | - | Through Hole | - | - | - | - |
|
JVA401500S15DC DC CONVERTER 15V 40W |
1,602 |
|
Datasheet |
JVA40 (40W) | 5-DIP Module | Box | Obsolete | Isolated Module | 1 | 200V | 1500V | 15V | - | - | - | 2.67A | 40 W | 4 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 70°C (With Derating) | 72% | - | - | Through Hole | - | - | - | - |
|
JVA401500S24DC DC CONVERTER 24V 40W |
3,523 |
|
Datasheet |
JVA40 (40W) | 5-DIP Module | Box | Obsolete | Isolated Module | 1 | 200V | 1500V | 24V | - | - | - | 1.67A | 40 W | 4 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 70°C (With Derating) | 72% | - | - | Through Hole | - | - | - | - |
|
PRQ150W-Q48-S5-DDC DC CONVERTER 5V 150W |
2,735 |
|
Datasheet |
PRQ150W | Quarter Brick | Tray | Not For New Designs | Isolated Module | 1 | 18V | 75V | 5V | - | - | - | 30A | 150 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 85°C (With Derating) | 88% | - | - | Through Hole | Quarter Brick | - | CE | 62368-1 |
|
RPP20-2412SDC DC CONVERTER 12V 20W |
3,811 |
|
Datasheet |
POWERLINE+ RPP20 (20W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 18V | 36V | 12V | - | - | - | 1.67A | - | 1.6 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -45°C ~ 99°C | 90.2% | - | - | Through Hole | - | - | - | - |
|
BMR4580012/002DC DC CONVERTER 12V |
3,483 |
|
Datasheet |
BMR458 | Quarter Brick | Tray | Active | Isolated Module, Digital | 1 | 36V | 75V | 12V | - | - | - | - | - | 2.25 kV | ITE (Commercial) | Adjustable Output, PMBus™, Remote On/Off, Remote Sense | -40°C ~ 125°C (With Derating) | - | - | - | Through Hole | Quarter Brick | Enable, Active Low | CB, CSA, IEC, TUV, UL | 62368-1 |